Door Flood Cut

Category: Mitigation

Principal Author(s): Sean Scott

Key Contributor(s): Seth Harrison, Mark Whatley, Janet Watkins

AI Board Approval: 05/19/2019

Last Update: 04/20/2021

Tags: Door, Flood, Jamb, Trim, Water

2 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 5 (2 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This was a residential (Class 3 | Cat 3) water loss that originated from a sewage backflow (foreign debris fill-up). The home was built in 1945 and constructed on a …

Hauling Debris

Category: Mitigation

Principal Author(s): Seth Harrison

Key Contributor(s): Mark Whatley, Daniel Smith, Janet Watkins

AI Board Approval: 04/07/2018

Last Update: 04/20/2021

Tags: Debris, Dumpster, Hauling, Trash

2 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 5 (2 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 3 | Cat 1) water loss. The scope of what this Insight Sheet seeks to explore is limited, thus a detailed back story is not …

Matterport Pro Series Scans

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): Dan Smith, Scott Black, Cynthia Parris

AI Board Approval: 11/21/2019

Last Update: 11/08/2020

Tags: 360 degree, AIMC, Cortex 3.0, Insta360, Invoicing for Matterport, MSP, Matterport, Post-mitigation, Pre-mitigation, Pro2 3D, Ricoh, Scan

5 votes, average: 4.20 out of 55 votes, average: 4.20 out of 55 votes, average: 4.20 out of 55 votes, average: 4.20 out of 55 votes, average: 4.20 out of 5 (5 votes, average: 4.20 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 2 | Cat 1) water loss. The scope of what this Insight Sheet seeks to explore is limited, thus a detailed back story is not …

Covered Plumbing Activities

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): Dan Smith, Scott Black

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Angle Stop, Covered Plumbing Activities, P-Trap, drain, pipes, plumbing

7 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 5 (7 votes, average: 4.43 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 3 | Cat 3) water loss. The scope of what this Insight Sheet seeks to explore is limited, thus a detailed back story is not necessarily …

Asbestos Abatement: Vinyl Tile & Mastic

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Abatement, Asbestos, Asbestos Abatement (Vinyl Tile & Mastic), Containment, Decontamination, HEPA, Hazardous, Mastic, Tile

6 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 5 (6 votes, average: 4.50 out of 5)
You need to be a registered member to rate this.
Loading...


This was a (Class 3 | Cat 1) residential water loss. The source of the water loss was a failed supply line associated with the toilet. Considerable amounts of water …

Microbial Remediation

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Microbial Remediation, Remediation

8 votes, average: 4.25 out of 58 votes, average: 4.25 out of 58 votes, average: 4.25 out of 58 votes, average: 4.25 out of 58 votes, average: 4.25 out of 5 (8 votes, average: 4.25 out of 5)
You need to be a registered member to rate this.
Loading...


This was a residential single story (Class 3 | Cat 1) water loss that transitioned into a Cat 3. The property owners were out of the home on holiday, and …

Textile Restoration

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Restoration, Textile, Textile Restoration, cleaning

5 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 5 (5 votes, average: 4.60 out of 5)
You need to be a registered member to rate this.
Loading...


This a residential fire of a single story Tudor style home that was caused by a faulty laptop battery charger.  The policyholders were not at home at the time of …

Negative Air Ducting

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Containment, Decontamination, Ducting, Equipment, Negative Air Ducting, lay flat

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 2 | Cat 3) soft clog fill-up water loss. The condo’s plumbing backed up to the extent that several condos were affected simultaneously. The policyholder …

Packout Vehicles

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Packback, Packout, Vehicle, car, transportation, truck, van

4 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 5 (4 votes, average: 4.75 out of 5)
You need to be a registered member to rate this.
Loading...


This Insight Sheet seeks to highlight the basic vehicle concessions associated with a standard two-day packout and two-day packback. The catalyst for the packout was a (Class 3 | Cat …

Vault Storage

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Packback, Packout, Storage, Storage Container, Vault

5 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 5 (5 votes, average: 4.40 out of 5)
You need to be a registered member to rate this.
Loading...


This Insight Sheet© seeks to illustrate best practices associated with invoicing for 6′ x 7′ x 7′ storage vaults stored in a climate controlled warehouse. The contents that were relocated …

Temporary Roof Tarping

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith, Daniel Meehan

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Mobilization, Sandbag, Temporary, roof, tarp

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This was a residential fire of a single story ranch style home that suffered significant wind damage. We intend to explore the activities associated with tarping the roof as there …

Temporary Water Heater

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith, Aaron Provencal

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Garage, Temporary, Water Heater, plumbing

5 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 5 (5 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a (Class 1 | Cat 1) water loss. The pre-existing water heater failed and the water ran down into the framed drywall stand. The water then ran under …

CAT 3 Extraction with Contents

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Cat, Cat 3, Contents, Decontamination, Extraction, Flood, Water

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 2 | Cat 3) soft clog fill-up water loss. The toilet internals failed to automatically shut off at height and the water ran for about …

EMS Activities (Post Fire)

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: EMS, EMS Activities, EMS Activities (Post Fire), Fire, Mitigation

5 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 55 votes, average: 4.40 out of 5 (5 votes, average: 4.40 out of 5)
You need to be a registered member to rate this.
Loading...


This a residential fire of a single-story ranch style home that was caused by a hoverboard battery failure while charging.  The policyholders were not home at the time of the …

Skid Plates

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Packback, Packout, Skid Plates

2 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 5 (2 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


Contents restoration and textile restoration reside beyond the scope of this Insight Sheet. This Insight Sheet exists to clarify how one might invoice for a piano packout and packback. This does …

On-site Storage Container

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, On-site, On-site Storage Container, Packback, Packout, Storage Container

5 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 55 votes, average: 4.60 out of 5 (5 votes, average: 4.60 out of 5)
You need to be a registered member to rate this.
Loading...


This was a (Class 2 | Cat 1) water loss. The loss was created by a PEX pipe failure located in the kitchen wall. The kitchen, living room, and small …

Off-Site Storage Container with Decontamination & After Hours

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Decontamination & After Hours, Off-Site Storage Container with Decontamination & After Hours, Off-site, Off-site Storage Container, Packback, Packout, Storage Container

6 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 56 votes, average: 4.50 out of 5 (6 votes, average: 4.50 out of 5)
You need to be a registered member to rate this.
Loading...


This was a residential (Class 2 | Cat 1) water loss. The loss was created by a hot water PEX pipe failure located in the kitchen wall. The Kitchen and, …

Off-site Storage Container

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Off-site, Off-site Storage Container, Packback, Packout, Storage Container

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This was a (Class 2 | Cat 1) water loss. The loss was created by a PEX pipe failure located in the kitchen wall. The kitchen, living room, and small …

Billiard Packout/Packback

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Billiard, Billiard Packout/Packback, Contents, Packback, Packout

3 votes, average: 3.67 out of 53 votes, average: 3.67 out of 53 votes, average: 3.67 out of 53 votes, average: 3.67 out of 53 votes, average: 3.67 out of 5 (3 votes, average: 3.67 out of 5)
You need to be a registered member to rate this.
Loading...


Contents restoration and textile restoration reside beyond the scope of this Insight Sheet. This Insight Sheet exists to clarify how one might invoice for a billiards table packout and packback. This …

Piano Packout/Packback

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Packback, Packout, Piano, Piano Packout/Packback

2 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 5 (2 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


Contents restoration and textile restoration reside beyond the scope of this Insight Sheet. This Insight Sheet exists to clarify how one might invoice for a piano packout and packback. This does …

Packout Materials

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Materials, Packout, Packout Materials

4 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 5 (4 votes, average: 4.75 out of 5)
You need to be a registered member to rate this.
Loading...


Contents restoration and textile restoration reside beyond the scope of this Insight Sheet. This Insight Sheet exists to clarify how one might invoice for packout and packback materials. This does not …

Packout/Packback Labor

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Contents, Labor, Packback, Packout, Packout/Packback Labor

4 votes, average: 4.50 out of 54 votes, average: 4.50 out of 54 votes, average: 4.50 out of 54 votes, average: 4.50 out of 54 votes, average: 4.50 out of 5 (4 votes, average: 4.50 out of 5)
You need to be a registered member to rate this.
Loading...


This is a single story (Class 3 | Cat 1) residential water loss. The policyholder was not in town at the time the hot water heater supply line failed. The …

Sunbelt Ladders

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Equipment, Ladders, Rental, Sunbelt, Sunbelt Ladders

2 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 52 votes, average: 5.00 out of 5 (2 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 1 | Cat 1) hail loss. The wind driven hail blew in sideways with such force it also damaged the siding. As a natural extension …

Sunbelt Scaffolding

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Equipment, Rental, Scaffolding, Sunbelt, Sunbelt Scaffolding

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a commercial (Class 3 | Cat 1) loss. A 6″ fresh water pipe on the 16th floor experienced a catastrophic failure. Water quickly filled the elevator shaft, and …

Sunbelt Scissor Lift

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Equipment, Lift, Rental, Sunbelt, Sunbelt Scissor Lift

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This is a commercial water loss (Class 2 | Cat 2). The water intrusion was caused by a failed ½” copper line. The water sprayed continuously for hours and soaked …

Sunbelt 250KW Generator

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Equipment, Generator, Rental, Sunbelt, Sunbelt 250KW Generator

5 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 5 (5 votes, average: 4.80 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level commercial water loss (Class 3 | Cat 1). The water was introduced to the property via a failed supply line on the second floor of the …

DriHeat VapairVent

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Air Mover, Containment, DriHeat, DriHeat VapairVent, Ductwork, Equipment, Performance Drying, Thermal

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a single-level residential water loss (Class 2 | Cat 1). DriHeat performance drying equipment was exclusively employed. This DriHeat VapairVent is intended to function as an ad-hoc dehu …

DriHeat Radial 8

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Air Mover, DriHeat, DriHeat Radial 8, Equipment, Performance Drying, Thermal

4 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 5 (4 votes, average: 4.75 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a single-level residential water loss (Class 2 | Cat 1). DriHeat performance drying equipment was exclusively employed, including the Power Distribution Box. Ultimately the performance drying was successful …

DriHeat Elite 52K

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Air Mover, DriHeat, DriHeat Elite 52K, Equipment, Performance Drying, Thermal

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a single-level residential water loss (Class 2 | Cat 1). DriHeat performance drying equipment was exclusively employed, including the Power Distribution Box. The project required remote monitoring to …

DriHeat Dual Element Heater

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Air Mover, DriHeat, DriHeat Dual Element Heater, Equipment, Performance Drying, Remote Monitoring

5 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 5 (5 votes, average: 4.80 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a single-level residential water loss (Class 2 | Cat 1). DriHeat performance drying equipment was exclusively employed. The project required remote monitoring to ensure the affected building material …

DriHeat ITA 75

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, DriHeat, DriHeat ITA75, Equipment, HEPA, Rental

6 votes, average: 4.17 out of 56 votes, average: 4.17 out of 56 votes, average: 4.17 out of 56 votes, average: 4.17 out of 56 votes, average: 4.17 out of 5 (6 votes, average: 4.17 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

DriHeat ITA 400

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, DriHeat, DriHeat ITA400, Equipment, HEPA, Rental

4 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 54 votes, average: 4.75 out of 5 (4 votes, average: 4.75 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

GMS Power Distribution Box

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: DriHeat, DriHeat Power Dist, Electrician, Equipment, Generator

6 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 5 (6 votes, average: 4.83 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level residential water loss (Class 3 | Cat 1). Considerable amounts of DriHeat performance drying equipment were exclusively employed, subsequently necessitating the use of a DriHeat Power …

DriHeat ELE

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Containment, Decontamination, DriHeat, DriHeat ELE, Ducting, Equipment, Thermal

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 2 | Cat 1). DriHeat performance drying equipment was exclusively employed (Power Distribution Boxes notwithstanding). Due to the fact that the Eliminator maintains …

DrySmart D500

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, DrySmart, DrySmart D500, Equipment, Rental, Trailer

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

DrySmart D330

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, DrySmart, DrySmart D330, Equipment, HEPA, Rental

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

DrySmart LP250

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, DrySmart, DrySmart LP250, Equipment, Generator, Performance Drying, Rental, Trailer

5 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 5 (5 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

TES 250k Trailer

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, Equipment, Performance Drying, Rental, TES 250k Trailer, Thermal, Trailer

5 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 55 votes, average: 5.00 out of 5 (5 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

Tes 200k Trailer

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Decontamination, Equipment, Performance Drying, Rental, Tes 200k Trailer, Thermal, Trailer

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 3). Prior to the loss, the area had experienced record low temperatures and this subsequently caused a drain pipe to …

E-TES Smart Dry

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Air Mover, Equipment, Performance Drying, Smart Dry, TES, Thermal

3 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 53 votes, average: 5.00 out of 5 (3 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a single-level residential water loss (Class 3 | Cat 1). E-TES performance drying equipment was exclusively employed. Ultimately the performance drying was successful in its efforts to mitigate …

Standard Dry Out Equipment & Monitoring

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith, Russ Palmer

AI Board Approval: 06/14/2017

Last Update: 04/20/2021

Tags: Appliance, Dry out, Equipment, Monitoring, dryout

4 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 54 votes, average: 5.00 out of 5 (4 votes, average: 5.00 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a residential multi-level (Class 1 | Cat 1) water loss. The clean water supply line associated with the dishwasher failed. The policyholder was in the kitchen at the …

Asbestos Abatement: Dropping Lid w/ Acoustic Texture

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith, Carlos Sanguinetti

AI Board Approval: 06/07/2017

Last Update: 04/20/2021

Tags: Abatement, Acoustic, Asbestos, Containment, Decontamination, HEPA, Hazardous, Lid, Texture

6 votes, average: 4.33 out of 56 votes, average: 4.33 out of 56 votes, average: 4.33 out of 56 votes, average: 4.33 out of 56 votes, average: 4.33 out of 5 (6 votes, average: 4.33 out of 5)
You need to be a registered member to rate this.
Loading...


This was a (Class 3 | Cat 1) residential water loss. The source of the water loss was a failed supply line associated with the upstairs toilet. The water ran …

Personal Protective Equipment – Cat 3

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Dan Smith

AI Board Approval: 07/07/2017

Last Update: 04/20/2021

Tags: Booties, Boots, Charge, Disposable, Face Shield, Gloves, HEPA, Heavy Duty, N-95, PPE, PPEs, Personal Protective Equipment, Respirator, Rubber, Suit

7 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 57 votes, average: 4.43 out of 5 (7 votes, average: 4.43 out of 5)
You need to be a registered member to rate this.
Loading...


This is a residential (Class 3 | Cat 3) water loss. The source of the loss was an upstairs toilet that suffered a catastrophic soft clog fill-up. The water near …

Infratech IR Lamp

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Glenn Wells, Dan Smith

AI Board Approval: 06/03/2017

Last Update: 04/20/2021

Tags: Drying, Equipment, Heat, IR, Infrared, Lamp, Performance, Thermal

6 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 56 votes, average: 4.83 out of 5 (6 votes, average: 4.83 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 1 | Cat 1). Ultimately the performance drying was successful in its efforts to mitigate additional damages and manage the overarching claim cost …

Injectidry Systems

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Ernie Storrer, Dan Smith

AI Board Approval: 02/04/2017

Last Update: 04/20/2021

Tags: Booster, Decontamination, Drying, Mats, Performance, Remote Monitoring, Thermal DBK, Wood Floor

5 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 55 votes, average: 4.80 out of 5 (5 votes, average: 4.80 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level water loss (Class 3 | Cat 1). The cause of loss was a supply line located under the sink in the upstairs bathroom. The policyholder noticed …

DBK Performance Dry Out Equipment

Category: Mitigation

Principal Author(s): Mark Whatley, Seth Harrison

Key Contributor(s): David Mattioli, Alan James, Dan Smith, Jakob Hibbard

AI Board Approval: 05/03/2017

Last Update: 04/20/2021

Tags: DBK, Drying, Drying Mats, Drymatic II, Equipment, Floor, Heat, Octopus., Performance, System, Thermal, Wall

8 votes, average: 4.88 out of 58 votes, average: 4.88 out of 58 votes, average: 4.88 out of 58 votes, average: 4.88 out of 58 votes, average: 4.88 out of 5 (8 votes, average: 4.88 out of 5)
You need to be a registered member to rate this.
Loading...


This assumes a multi-level Class 3 | CAT 1 water loss. DBK performance drying equipment was exclusively employed (Power Distribution Boxes notwithstanding). The project required extensive remote monitoring. The sensors …